MVA A2 (AASC) Bare Overhead Conductor

Aluminum Alloy Conductor Concentric-Lay-Stranded

 

A2 (AASC), ALUMINUM ALLOY CONDUCTOR, CONCENTRIC-LAY-STRANDED (MECHANICAL PROPERTIES)- CONDUCTOR SIZED TO HAVE DIAMETER EQUAL TO ACSR
CODE WORD
CSA DESIGNATION CONDUCTOR SIZE EQUIVALENT ACSR SIZE (I)
EQUIVALENT ASC SIZE (2)
STRANDING NO. X DIA. (mm)
CLASS
 
O.D.(nm)
NOMINAL MASS KG/KM
RATED STRENGTH kN
kcmil mm2
 
none 8-P\2.-7 18.9 9.6 18.9 18.9 7x1.32 AA 3.96 26.15 2.92
Fredericton 13-P\2.-7 30.2 15.3 #6 #6 7x1.67 AA 5.01 41.86 4.68
Whitehorse 21-P\2.-7 48.0 24.3 #4 #4 7x2.10 AA 6.30 66.19 7.39
Halifax 34-P\2.-7 76.4 38.7 #2 #2 7x2.65 AA 7.95 105.4 11.8
Regina 42-P\2.-7 96.3 48.8 #1 #1 7x2.98 AA 8.94 133.3 14.9
Montreal 54-P\2.-7 121.5 61.6 1/0 1/0 7x3.35 AA 10.1 168.4 18.8
Winnipeg 67-P\2.-7 153.2 77.6 2/0 2/0 7x3.76 AA 11.3 212.2 23.7
Toronto 85-P\2.-7 193.1 97.9 3/0 3/0 7x4.22 AA 12.7 267.3 29.9
Vancouver 107-P\2.-7 243.5 123.4 4/0 4/0 7x4.74 AA 14.2 337.2 37.7
Calgary 135-P\2.-19 307.1 155.6 266.8 266.8 19x3.23 AA 16.2 426.8 47.5
Edmonton 170-P\2.-19 387.2 196.2 336.4 336.4 19x3.63 AA 18.2 539.1 60.0
Brockville 201-P\2.-19 457.5 231.8 397.5 397.5 19x3.94 AA 19.7 635.1 70.7
Quebec 242-P\2.-19 549.0 278.2 477 477 19x4.32 AA 21.6 763.5 84.9
(1) Equivalent ACSR Size refers to an ACSR conductor size of equal diameter.                                                                            
(2) Equivalent ASC Size refers to an ASC (i.e., CSA C61089 A1) conductor of approximate equivalent electrical resistance.                                                                                
Dimensions and weights not designated minimum or maximum are nominal values and subject to manufacturing tolerances_  In this context. weight means mass                                              
A2 (AASC), ALUMINUM ALLOY CONDUCTOR,CONCENTRIC-LAY-STRANDED (ELECTRICAL PROPERTIES) - CONDUCTOR SIZED TO HAVE DIAMETER EQUAL TO ACSR
CODE WORD
CONDUCTOR SIZE RESISTANCE (3)0HMS/KM AMPACITY @75'C (4) GEOMETRIC MEAN RADIUS CM
INDUCTIVE REACTANCE OHM/KM (5)
CAPACITIVE REACTANCE MEGAOHM-KM (5)
kcmil mm2 DC @20'C
AC @25'C
AC @75'C
STANDARD E3X"'
none 18.9 9.6 3.433 3.493 4.093 73 78 0.143 0.4042 0.2404
Fredericton 30.2 15.3 2.154 2.192 2.568 98 105 0.183 0.3858 0.2293
Whitehorse 48.0 24.3 1.354 1.378 1.615 131 141 0.229 0.3688 0.2182
Halifax 76.4 38.7 0.8515 0.8665 1.015 175 191 0.290 0.3511 0.2071
Regina 96.3 48.8 0.6751 0.6871 0.8052 202 222 0.323 0.3429 0.2016
Montreal 121.5 61.6 0.5350 0.5445 0.6382 234 258 0.366 0.3333 0.1960
Winnipeg 153.2 77.6 0.4245 0.4321 0.5064 270 299 0.408 0.3251 0.1905
Toronto 193.1 97.9 0.3367 0.3428 0.4017 313 348 0.460 0.3163 0.1850
Vancouver 243.5 123.4 0.2670 0.2720 0.3187 362 404 0.515 0.3078 0.1795
Calgary 307.1 155.6 0.2127 0.2168 0.2540 418 471 0.613 0.2946 0.1734
Edmonton 387.2 196.2 0.1687 0.1722 0.2016 484 548 0.686 0.2861 0.1678
Brockvile 457.5 231.8 0.1428 0.1459 0.1708 537 611 0.747 0.2795 0.1638
Quebec 549.0 278.2 0.1190 0.1218 0.1425 602 688 0.817 0.2730 0.1595
(3) Based on a conductivity of 53.0% IACS at 20˚C for aluminum.
(4) Based on a conductor temperature of 75°C at 60 Hz and the following conditions, 32°C ambient temperature, 1.98 ft/sec (0.6 m/sec) crosswind (90° to conductor), 0.5 coefficient
of emissivity for a standard conductor and 0.9 for a E3X coated conductor, 0.5 coefficient of absorptivity for a standard conductor and 0.2 for a E3X coated conductor, 42° northern
 latitude, sea level elevation, 90° azimuth of line (East-West), clear atmosphere, and a date and time of noon on July 1 (resulting in 95.0 W/ft² of solar and sky radiated heat). 
Actual ampacity will differ based on local conditions. For specific ampacities, please contact your MVA Power sales representative.                                                                            
(5) Values for inductive reactance and capacitive reactance are expressed in terms of a 1 ft radius (30.48 cm).