Material: Hot-Dip Galvanized Steel Per ASTM A153 & CSA G164
Capacities Helical Torque Anchors
Shaft Size | Installation Torque Factor (k) | Axial Compression Load Limit | Ultimate Limit Tension Strength | Useable Torsional Strength | Practical Load Limit Based Torsinnal Strength |
lb | lb | lb | |||
1-1/2 Square Bar | 9-11 | 70 000 | 70 000 | 7500 ft-lb | Load limited to the rated capacity of the attachment and the lateral soil strength against the shaft |
1-3/4 Square Bar | 9-11 | 100000 | 100000 | 10000 ft-lb | |
2-1/4 Square Bar | 10-12 | 200000 | 200000 | 23000 ft-lb | |
2-7/8 Tubular - 0.262*Wall | 8-9 | 100000 | 100000 | 9500 ft-lb | 80 000 |
3-1/2 Tubular - 0.300*Wall | 7-8 | 115000 | 120000 | 13000 ft-lb | 97 000 |
4-1/2 Tubular - 0.337*Wall | 6-7 | 160000 | 160000 | 22000 ft-lb | 143 000 |
3-1/2'' Helical Extensions
Part # | Size | Length | # Helix | Helix Dia. |
inch | inch | inch | ||
THE-350-36 | 3-1/2 | 36 | 0 | NA |
THE-350-60 | 3-1/2 | 60 | 0 | NA |
THE-350-84 | 3-1/2 | 84 | 0 | NA |
THE-350-36-14 | 3-1/2 | 36 | 1 | 14 |
THE-350-60-14 | 3-1/2 | 60 | 1 | 14 |
THE-350-60-12-14 | 3-1/2 | 60 | 2 | 12.14 |
3-1/2'' 115,000# Compression Helical Piles
Part # | Size | Length | # Helix | Helix Dia. |
inch | inch | inch | ||
THA-350-60-12 | 3-1/2 | 60 | 1 | 12 |
THA-350-60-8-10 | 3-1/2 | 60 | 2 | 8,10 |
THA-350-60-10-12 | 3-1/2 | 60 | 2 | 10,12 |
THA-350-84-10-12 | 3-1/2 | 84 | 2 | 10,12 |
THA-350-84-12-14 | 3-1/2 | 84 | 2 | 12,14 |
THA-350-84-8-10-12 | 3-1/2 | 84 | 3 | 8,10,12 |
THA-350-84-10-12-14 | 3-1/2 | 84 | 3 | 10,12,14 |
Standard Torque Anchor Lead Configurations